Labo DGCAM 1000 Digital Camera Keywords: Digital Camera, CCD Camera, Image Analysis Software
Digital Camera Module Specifications 1/3" Color CCD sensor Effective pixels 795 (H) x 596 (V) Still image resolution 720 x 576 pixels (PAL), 720 x 480 (NTSC) Scanning system: Up to 25 fps at 720 x 576 for PAL, 30 fps at 720 x 480 for NTSC Data Transfer: 7.5 MB/second Minimum Illumination: 0.8 lux, f1.2 5600°K With C mount, Automatic Shutter, Automatic White Balance In-built signal converter from Analog to Digital Output: USB v2.0, S-Video and Composite Video Output Operating system requirement: Windows? 2000 and above
dgsoft proMED v5.06 Image analysis software for image capturing, analysis and measurement.
Features include User Friendly Installation; Capturing: Still , Video, Video with Audio, Time lapse video & still capturing, IMAGE EDITING: Cut, Copy, and Paste; Crop, duplicate, restore; Resize; Compression; Conversion to other format BMP, JPG, TIF, PNG, GIF & PSD; Grid creation; VIEW: Zoom in/out; Zoomed preview; Rotation at 90, 180,270 or custom; Image flipping; horizontal or vertical axis; Intensity histogram; Image Information; Redo/Undo on all operations; Ruler in Various units; Slide show. IMAGE PROCESSING: Background subtraction and contrast enhancement of color or monochrome images; Arithmetic image functions (Boolean Math; Add, AND, OR, XOR, DIFF, MIN, MAX, +, -, /, *, And Simple). ROUTINE FILTERS: Invert, Brightness, Contrast, Hue, Saturation, Blur, Noise Remove, Emboss, Engrave, Gamma R, Gamma G, Gamma B, Yellow, Magenta, Cyan, Mosaic, Smooth, Desaturation, Pseudo Color, Colorize, Oilify, Despeckle, Postarize. SPECIAL FILTERS & KARNELS: High Boost, High Spatial, Low Pass Spatial, Ranking (Max, Med, Min), Point detection, Line detection, Homogeneity. EDGE DETECTION: Lap lacing, Sobel, Kirsch, Prewitt Gradient, Shift & Difference, Combine, Contrast Base, Quick, Range And Variance. MORPHOMETERY: Skelotizing, Pruning, SKIZ, Histogram Equalization, Histogram Smoothing, Histogram Peak, Histogram Valley, Segmentation by Over/Under and Quantized,Contouring, Dilation etc.; Image Addition, Image Average, Image Subtraction, Image Multiplication. MEASUREMENT: Spartial calibration; Line measurements for Distance, Length, Width, Perimeter, Angle, Three Point Radius; Area by enclosed line controlled by four arrow keys available on keyboard arrows with zoomed preview. COUNT AND CLASSIFICATION: Identification of objects in an image, count them, obtain several features measurements. Objects identification by user or automatically. User defined classification on basis of size or intensity. THRESHOLD PARTICLE MEASUREMENT: Manual, Auto bright and Auto dark methods to identity intensity range defined object to be measured. Various calculation & measurements available for selected Particle are; Dimensions, Area, Perimeter, Ferrite Length, Min/Max Radius, Thread Length, Thread Width, Fiber Length, Fiber Width. MORPHOMETERY: Roundness, Shape, Orientation, Elongation, Equal Circular Diameter, Equal Sphere Volume. LOCATIONAL: Centroid X, Centroid Y, Major X1, Major Y1, Minor X1, Minor Y1, Major X2, Major Y, Major X2, Minor Y2, Box X1, Box X2, Box Y, Box Y2 & Box Area. SEGMENTATION: Measure area fraction & volume fraction. Identify multiple phases within Microstructure. Also delineate phases from the histogram. REPORT: Three options: Direct printout with original image processed Image & Tabular results; Export to MS Office or Excel for further modification.
Packed in cardboard box with adapter, USB cable, Software CD, Composite video cable, 12V external power supply and operation manu |
|
|
|
|
|
 Click image to enlarge |
Labo DGCAM 1300 Digital Camera Keywords: Digital Camera,CMOS Camera,Image Analysis Software
Digital Camera Module 1.3 Mega pixel Specifications: 1/3? Color CMOS sensor Effective Pixels 1280 (H) x 960 (V) Scanning system: Progressive scan Frame speed: 15 fps at 1280 x 960 With C mount, Automatic Shutter, Automatic White Balance Communication protocol : USB v2.0 Operating system requirement: Windows? 2000 and above
dgsoft proMED v5.06 Image analysis software for image capturing, analysis and measurement.
Features include User Friendly Installation; Capturing: Still , Video, Video with Audio, Time lapse video & still capturing, IMAGE EDITING: Cut, Copy, and Paste; Crop, duplicate, restore; Resize; Compression; Conversion to other format BMP, JPG, TIF, PNG, GIF & PSD; Grid creation; VIEW: Zoom in/out; Zoomed preview; Rotation at 90, 180,270 or custom; Image flipping; horizontal or vertical axis; Intensity histogram; Image Information; Redo/Undo on all operations; Ruler in Various units; Slide show. IMAGE PROCESSING: Background subtraction and contrast enhancement of color or monochrome images; Arithmetic image functions (Boolean Math; Add, AND, OR, XOR, DIFF, MIN, MAX, +, -, /, *, And Simple). ROUTINE FILTERS: Invert, Brightness, Contrast, Hue, Saturation, Blur, Noise Remove, Emboss, Engrave, Gamma R, Gamma G, Gamma B, Yellow, Magenta, Cyan, Mosaic, Smooth, Desaturation, Pseudo Color, Colorize, Oilify, Despeckle, Postarize. SPECIAL FILTERS & KARNELS: High Boost, High Spatial, Low Pass Spatial, Ranking (Max, Med, Min), Point detection, Line detection, Homogeneity. EDGE DETECTION: Lap lacing, Sobel, Kirsch, Prewitt Gradient, Shift & Difference, Combine, Contrast Base, Quick, Range And Variance. MORPHOMETERY: Skelotizing, Pruning, SKIZ, Histogram Equalization, Histogram Smoothing, Histogram Peak, Histogram Valley, Segmentation by Over/Under and Quantized,Contouring, Dilation etc.; Image Addition, Image Average, Image Subtraction, Image Multiplication. MEASUREMENT: Spartial calibration; Line measurements for Distance, Length, Width, Perimeter, Angle, Three Point Radius; Area by enclosed line controlled by four arrow keys available on keyboard arrows with zoomed preview. COUNT AND CLASSIFICATION: Identification of objects in an image, count them, obtain several features measurements. Objects identification by user or automatically. User defined classification on basis of size or intensity. THRESHOLD PARTICLE MEASUREMENT: Manual, Auto bright and Auto dark methods to identity intensity range defined object to be measured. Various calculation & measurements available for selected Particle are; Dimensions, Area, Perimeter, Ferrite Length, Min/Max Radius, Thread Length, Thread Width, Fiber Length, Fiber Width. MORPHOMETERY: Roundness, Shape, Orientation, Elongation, Equal Circular Diameter, Equal Sphere Volume. LOCATIONAL: Centroid X, Centroid Y, Major X1, Major Y1, Minor X1, Minor Y1, Major X2, Major Y, Major X2, Minor Y2, Box X1, Box X2, Box Y, Box Y2 & Box Area. SEGMENTATION: Measure area fraction & volume fraction. Identify multiple phases within Microstructure. Also delineate phases from the histogram. REPORT: Three options: Direct printout with original image processed Image & Tabular results; Export to MS Office or Excel for further modification.
Packed in cardboard box with adapter, USB cable, Composite video cable, Software CD and operation manual. |
|
|
|
|
|
 Click image to enlarge |
Labo DGCAM 3000 Digital Camera Keywords: Digital Camera,CMOS Camera, Image Analysis Software
Digital Camera Module 3.1 Mega pixel
Specifications: 1/3" Color sensor Effective pixels 2048 x 1536, 3.2um square pixels Frame Rate: 20 frames/second at 1024x768 pixels Scanning system: Progressive Scan Illumination sensitivity: High With C mount, Automatic Shutter, Automatic/Manual White Balance, Automatic/Manual, Exposure controls Communication Protocol: USB v2.0 Operating system requirement: Windows? 2000 and above dgsoft proMED v5.06 Image analysis software for image capturing, analysis and measurement.
Features include User Friendly Installation; Capturing: Still , Video, Video with Audio, Time lapse video & still capturing, IMAGE EDITING: Cut, Copy, and Paste; Crop, duplicate, restore; Resize; Compression; Conversion to other format BMP, JPG, TIF, PNG, GIF & PSD; Grid creation; VIEW: Zoom in/out; Zoomed preview; Rotation at 90, 180,270 or custom; Image flipping; horizontal or vertical axis; Intensity histogram; Image Information; Redo/Undo on all operations; Ruler in Various units; Slide show. IMAGE PROCESSING: Background subtraction and contrast enhancement of color or monochrome images; Arithmetic image functions (Boolean Math; Add, AND, OR, XOR, DIFF, MIN, MAX, +, -, /, *, And Simple). ROUTINE FILTERS: Invert, Brightness, Contrast, Hue, Saturation, Blur, Noise Remove, Emboss, Engrave, Gamma R, Gamma G, Gamma B, Yellow, Magenta, Cyan, Mosaic, Smooth, Desaturation, Pseudo Color, Colorize, Oilify, Despeckle, Postarize. SPECIAL FILTERS & KARNELS: High Boost, High Spatial, Low Pass Spatial, Ranking (Max, Med, Min), Point detection, Line detection, Homogeneity. EDGE DETECTION: Lap lacing, Sobel, Kirsch, Prewitt Gradient, Shift & Difference, Combine, Contrast Base, Quick, Range And Variance. MORPHOMETERY: Skelotizing, Pruning, SKIZ, Histogram Equalization, Histogram Smoothing, Histogram Peak, Histogram Valley, Segmentation by Over/Under and Quantized,Contouring, Dilation etc.; Image Addition, Image Average, Image Subtraction, Image Multiplication. MEASUREMENT: Spartial calibration; Line measurements for Distance, Length, Width, Perimeter, Angle, Three Point Radius; Area by enclosed line controlled by four arrow keys available on keyboard arrows with zoomed preview. COUNT AND CLASSIFICATION: Identification of objects in an image, count them, obtain several features measurements. Objects identification by user or automatically. User defined classification on basis of size or intensity. THRESHOLD PARTICLE MEASUREMENT: Manual, Auto bright and Auto dark methods to identity intensity range defined object to be measured. Various calculation & measurements available for selected Particle are; Dimensions, Area, Perimeter, Ferrite Length, Min/Max Radius, Thread Length, Thread Width, Fiber Length, Fiber Width. MORPHOMETERY: Roundness, Shape, Orientation, Elongation, Equal Circular Diameter, Equal Sphere Volume. LOCATIONAL: Centroid X, Centroid Y, Major X1, Major Y1, Minor X1, Minor Y1, Major X2, Major Y, Major X2, Minor Y2, Box X1, Box X2, Box Y, Box Y2 & Box Area. SEGMENTATION: Measure area fraction & volume fraction. Identify multiple phases within Microstructure. Also delineate phases from the histogram. REPORT: Three options: Direct printout with original image processed Image & Tabular results; Export to MS Office or Excel for further modification.
Packed in cardboard box with adapter, USB cable, Composite video cable, Software CD and operation manual. |
|
|
|
|
|